Review 94 NS0-180 practice questions with answer explanations and community insights.
Question 1
You want to create a data volume on aggr0 and you receive a message with the following warning: ''Warning: You are about to create a volume on a root aggregate. This may cause severe performance or stability problems and therefore is not recommended. Do you want to proceed?'' What is the reason for this severe performance or stability problem?
Controller failover and storage failover are separate processes that must occur in parallel, otherwise problems will arise.
The performance load generated by the data volume can be very strong, so it should not be shared with vol0 on aggr0, requiring a separate aggregate for it.
The performance load generated by the vol0 cannot be shared with any other volume on aggr0, requiring a dedicated aggregate for it.
Controller failover and storage failover are separate processes that must occur at different times, otherwise problems will arise.
Question 2
You have completed a clustered Data ONTAP installation for a new customer. You are now ready to hand off the system to the customer. Which three actions should you take at this stage in the installation process? (Choose three.)
Show the customer how to open a case with NetApp Support.
Demonstrate System Manager and its functionality.
Tell the customer to call their sales representative if there are further questions.
Tell the customer you are finished and then leave the site.
Show the customer how to set up a support account.
Question 3
What happens to the NTP configuration in clustered Data ONTAP 8.3 when a node joins a cluster?
A node that joins a cluster has a separate NTP service.
A node that joins a cluster automatically adopts the NTP configuration of the cluster.
A node that joins a cluster must be manually configured in the NTP.
A node that joins a cluster must reboot before running the NTP service.
Question 4
You are assigned to install five DS2246 with twenty-four 400 GB SSDs per shelf to a single node system. According the NetApp, which statement is correct?
You cannot install five SSD shelves to one System.
You need at least two stacks.
You need at least three stacks.
You can put all shelves in one stack.
Question 5
Which three types of interface groups are supported on NetApp storage systems? (Choose three.)
single mode
HA interconnect
IPspaces
static multimode
dynamic multimode
We are moving to a new platform